Measurement MCQs |
1. A D'Arsonval movement is_______.
a. Moving iron type
b. Electrodynamometer
c. PMMC
d. Taut band
2. What is the value of
multiplier resistance on the 50 V range of a dc voltmeter that uses a 500 μA meter movement with an internal resistance of 1 kΩ?
a. 119 kΩ
b. 99 kΩ
c. 199 kΩ
d. 109 kΩ
3. Loading effect in a voltmeter can be avoided by________.
a. Using a low sensitive voltmeter
b. Using an accurate and
precise instrument
c. Using a high sensitive voltmeter
d. Using high voltage range
4. In a D'Arsonval galvanometer, an iron core is usually used between
the permanent magnet pole faces. This is used so that_________.
a. The effect of stray magnetic fields is reduced
b. Flux density in the air gap
becomes high, thereby a large deflecting torque is produced
c. Moment of inertia of moving parts becomes smaller
d. None of the above
5. The sensitivity of a voltmeter is defined as________.
a. Ω/I
b. I/Ω
c. V/Ω
d. Ω/V
6. A diode used as rectifier in ac voltmeter should have_______.
a. Low forward current and low reverse current
b. Low forward current and high reverse current
c. High forward current and high reverse current
d. High forward current and low
reverse current
7. The ac voltmeter using PMMC measures__________.
a. Instantaneous voltage
b. Average voltage
c. Peak voltage
d. True RMS voltage
8. The ohm per volt rating on ac ranges as compared to the same rating
on dc ranges is__________.
a. Equal
b. More
c. Less
d. None of the above
9. Assertion: In case of moving iron instruments, accurate reading of
current is not possible at the lower end.
Reason : The scale of moving iron instruments is cramped at the lower
end.
a. 'A' is false, but 'R' is true
b. 'A' is true, but 'R' is false
c. Both 'A' and 'R' are, but 'R' is not a correct explanation of A
d. Both 'A' and 'R' are true,
and 'R' is a correct explanation of A
10. Swamping resistance is connected_______.
a. In series with meter and have high resistance temperature
coefficient in order to reduce errors in ammeter
b. In series with the meter and
have a negligible resistance coefficient in order to reduce temperature errors
in shunted ammeters
c. In series with the shunt to reduce temperature error in shunted
ammeters
d. In series with the ammeters to reduce errors on account of friction
11. Horizontally mounted moving iron instruments use_______.
a. Eddy current damping
b. Fluid friction damping
c. Electromagnetic damping
d. Air friction damping
12. A static movement in an electrodynamometer type of
instrument is used for________.
a. Eliminating error on the account of low torque to weight ratio
b. Increasing the operating torque of the instruments
c. Eliminating errors on
account of external magnetic fields
d. Providing eddy current damping
13. The thermocouple type of instruments can be used to
measure__________.
a. Both a.c and d.c values of
voltage and current
b. Both a.c and d.c values of current only
c. a.c current only
d. d.c. current only
14. Which of the following is not an electrothermic type of
instrument?
a. Hot wire instruments
b. Thermocouple instruments
c. PMMC instruments
d. Bolometer
15. Error due to hysteresis is predominant in__________.
a. Hot-wire instruments
b. Moving iron instruments
c. Electrodynamometer type instruments
d. Moving coil instruments