MCQs on DMAES Part1

1) For voltage boosting in distribution networks the capacitors used is_________.

a. Series capacitors

b. Shunt capacitors

c. Both (a) and (b)

d. None of these


2)   To reduce the power consumption, the capacitors should be located___________


a. As close as possible to the load

b. As far as possible to the load

c. Not too close not too far from the load

d. All of these

e. None of these

 

3)   In order to improve the power factor of equipment operating at lagging power factor, a capacitor is connected___________


a. In series with the equipment

b. In parallel with the equipment

c. In series-parallel with the equipment

d. Either (a) or (b)

 

4)   The secondary distribution transformer is generally___________


a. Star connected

b. Star connected with the secondary delta connected

c. Delta connected with the secondary star connected

d. Delta connected

 

5)   The ratio of average load over a designated period to the peak load demand occurring in that period is known as___________

a. power factor

b. ratchet rate

c. load factor

d. production factor

 

6)   The production factor is defined as the ratio of___________

a. current year production to the reference year production

b. current year production to the reference month production

c. reference month production to the current month production

d. reference year production to the current year production

 

7)   The reactive power component kVAR is equal to the___________

a. kVA sin∅

b. kW tan∅

c. kW cos∅

d. Both (a) and (b)

e. None of these

 

8)   The rotational speed of an AC induction motor depends on the___________

a. Number of poles in stator

b. Frequency of the applied AC power

c. Both a and b

d. None of these

 

 

9)   The monitor and control of energy management system is done by using___________

a. MATLAB

b. SCADA( Supervisory Control and Data Acquisition)

c. AUTO - CAD

d. All of these

e. None of these

 

10)   The water pollution prevention and control act was formed in the year___________

a. 1986

b. 1974

c. 1981

d. 1980

 

11)   The Indian electricity rules of 1956 cover___________

a. Inspections of electric installations

b. Licensing

c. General safety precautions

d. Only b and c

e. All of these

 

12)   Energy conservation act was formed in the year___________

a. 1998

b. 1999

c. 2000

d. 2001

 

13)   The rules of a particular electricity supply system provision for metering, earthing and for other installation matters are in accordance with the electricity supply act of___________

a. 1947

b. 1948

c. 1956

d. 1958

 

14)   Phase advancers are used to improve the power factor of___________

a. Induction motors

b. Induction generators

c. Synchronous motors

d. Synchronous generators

 

15)   Power factor of a load can be improved by using___________

a. Static capacitors

b. Synchronous condenser

c. Phase advancer

d. Only a and b

e. All of the above

 

16)   If power factor is less than unity then it will result in___________

a. Large kVA rating of equipment

b. Greater conductor size

c. Large copper losses

d. Only A and C

e. All of these

 

17)   If the load current decreases then the power factor___________

a. Will also decrease

b. Will increase

c. Will remains unchanged

d. None of these


18)   Reactive power is measured in terms of___________

a. kW

b. kVA

c. kVAR

d. None of these

 

19)   Power factor is the ratio of___________

a. Active power to the reactive power

b. Active power to the apparent power

c. Apparent power to the active power

d. Reactive power to the apparent power

 

20)   For a typical AC power supply, the secondary transmission carries the voltage of___________

a. 11kV

b. 33 kV

c. 66 kV

d. 132 kV

 

21)   The electric power from primary distribution line is delivered to distribution substations by using___________

a. 1 phase wire

b. 3 phase, 3 wire

c. 3 phase, 4 wire

d. All of these

e. None of these

 

22)   The reduction of utility load primarily during peak demand is known as___________

a. Peak clipping

b. Load shifting

c. Valley filling

d. MTP analysis

 

23)   IFMA stands for___________

a. International Facility Management Association

b. Indian Facility Management Association

c. International Facility Management Academy

d. Indian Facility Management Academy

 

24)   Maximum demand charges are given in___________

a. kWh

b. kVA

c. kVAr

d. All of these

e. None of these

 

25)   Energy management is a key component of___________

a. Environmental management

b. Carbon management

c. Nitrogen management

d. Water management

 