Measurement MCQs |
Multiple Choice question(MCQs) on transducers
1. A thermocouple is used
to measure in the range of 700oC
to 800oC. Select the pair that would be most suitable for the
applications.
a. Iron-constantan
b. Platinum-platinum + rhodium
c. Copper-constantan
d. Chromel-alumel
2. The transducer suited for
high temperature and fast response time is a ________.
a. Bimetallic strip
b. Thermocouple
c. Thermistor
d. RTD
3. Rota meter is a flow meter based on_________.
a. Variable pressure
b. Variable length
c. Variable area
d. None of these
4. In a thermocouple
element, heat energy transferred to the hot junction is converted into
electrical energy by_______.
a. Seebeck effect
b. Johnson's effect
c. Faraday's effect
d. Hall effect
5. Which of the following is
not a pair of active transducers?
a. LVDT and potentiometer
b. Photo-voltaic cell and
thermocouple
c. Piezoelectric transducer
and tachnogenerator
d. Accelerometer and
thermocouple
6. RTD is / an ________.
a. Capacitive transducer
b. Inductive transducer
c. Passive transducer
d. Active transducer
7. A thermistor is
inherently suitable temperature measurement involving_______.
a. Low span and low
sensitivity
b. High span and high
sensitivity
c.Low span but high sensitivity
d. High span but low
sensitivity
8. While selecting a
transducer for a particular application________.
a. Input, output and transfer characteristics should be considered
b. Only the input
characteristics should be considered
c. Only the transfer
characteristics should be considered
d. Only the output
characteristics should be considered
9. Capacitive transducers are
generally used for ________.
a. Static measurement
b. Dynamic measurement
c. Transient measurement
d. Both static and dynamic
measurement
10. Ceramic materials used
for piezo-electric transducers_______.
a. Are basically made of
barium titanate
b. Are polycrystalline in
nature
c. Do not have
piezo-electric properties in their original state, but these properties are
produced by special polarizing treatment
d. All of the above
11. The rotor of a
synchro-transmitter_________.
a. May use either salient or
cylindrical type of construction
b. Uses a cylindrical pole
type of construction
c. Uses a salient pole type of construction
d. None of the above
12. The lower limit of
useful working range of a transducer is determined by_______.
a. Minimum useful input
level
b. By transducer error and noise
c. Dynamic response
d. Cross sensitivity
13. Measurement of power at
high frequencies and thermal conductivity is determined by______.
a. Thermocouple
b. LVDT
c. Thermistor
d. None of these
14. Rochelle salt is a
crystalline material used in producing___________.
a. Differential transformer
transducer
b. Piezoelectric transducer
c. Photoelectric transducer
d. Velocity transducer
15. Measurement of flow,
thermal conductivity and liquid level using thermistors make use of __________.
a. Change of resistivity
b. Self-heating phenomenon
c. Resistance increase with
temperature
d. Resistance decrease with temperature