| Measurement MCQs |
1. A PMMC instrument can be
used as a fluxmeter by________.
a. Using low resistance
shunt
b. Removing the control springs
c. Making the control
springs of large moment of inertia
d. Using a high series
resistance
2. Flux meter is a special
type of ballistic galvanometer provided with which one of the following ?
a. Large controlling torque
and small electromagnetic damping
b. Small electromagnetic
damping and controlling torque
c. Heavy electromagnetic
damping and large controlling torque
d. Heavy electromagnetic damping and very small controlling torque
3. In a flux meter, the
controlling torque is________.
a. Provided by crosses-coil
mechanism
b. Produced by spring
c. Not provided at all
d. Produced by weight attached
to the moving coil
4. What is connected across
a flux meter for its effective functioning to measure magnetic flux density and
also to compare the strengths of permanent magnets ?
a. A search coil
b. A capacitor
c. A transformer
d. A resistor
5. Analog panel meters
basically measure_____.
a. Depends upon parameters
b. Power
c. Current
d. Voltage
6. A moving coil galvanometer is made into a dc
ammeter by connecting_________.
a. A capacitor in series
with the meter
b. A pure inductance across
the meter
c. A high resistance in
series with the meter
d. A low resistance across the meter
7. The internal resistance
of the milliammeter must be very low for ________.
a. Minimum effect on the current in the circuit
b. Maximum voltage drop
across the meter
c. High accuracy
d. High sensitivity
8. A very accurate voltmeter
gives inaccurate reading when used for measuring voltage across a low
resistance because____________.
a. The higher scale has been
selected
b. The voltmeter is making
too low current
c. The meter sensitivity is
too high
d. The meter sensitivity is too low
9. Which one of the
following statement is correct ?
Spiral springs are used in
instruments to
a. Provide controlling
torque
b. Provide damping torque
c. Lead the current to the moving coil as well as to provide the controlling
torque
d. Provide linear deflection
10. A mangnin swamp
resistance is connected in series with a moving coil ammeter consisting of a
milliammeter and suitable shunt in order to________.
a. Minimize the effect of
stray magnetic fields
b. Reduce the size of the
meter
c. Obtain large deflecting
torque
d. Minimize the effect of temperature variation
11. Eddy current damping
cannot be used for moving iron instruments because_______.
a. Weight of the instrument
will increase
b. Size of the instrument
will increase
c. Presence of permanent magnet will distort the magnetic field produced by
the instrument and hence will affect its readings
d. Eddy currents will pass
through the iron thereby cause losses
12. Hysteresis error, in
moving iron instruments, may be reduced by using_______.
a. High speed steel
b. Silver coating
c. Stainless steel
d. Permalloy
13. An advantage of a PMMC
instrument is that it is________.
a. Free from Friction error
b. Has high(torque/weight of the moving parts) ratio
c. Has low(torque/weight of
the moving parts) ratio
d. can be used on both ac
and dc
14. The term artificial
aging is associated with__________.
a. Damping
b. Controlling torques
c. Permanent magnets
d. Springs
15. Moving iron and PMMC
instrument can be distinguished from each other by looking at______.
a. Scale range
b. Terminal size
c. Pointer
d. Scale
16. The scale of a
dynamometer type instrument marked in terms of rm value would be______.
a. Nonuniform crowded around
midscale
b. Nonuniform crowded at the beginning
c. Nonuniform crowded near full scale
d. Uniform throughout
17. In a dynamometer type
moving coil instrument a swamping resistance is provided in order to______.
a. Provide equal time constant for moving coil and fixed coil, when used
for ac measurement
b. Reduce the current
flowing through the moving coil
c. Reduce the bulk of the
moving system
d. Control the deflecting
torque
18. Electrodynamometer type
of instrument can be used to measure ______.
a. AC only
b. DC only
c. Both AC and DC
d. None of the above
19. Which one of the
following statement is correct?
The deflection of a hot-wire
instrument depends on_______.
a. Average value of the ac
voltage
b. Average value of the ac current
c. RMS value of the ac
voltage
d. RMS value of the ac current
20. Which of the following
statements is not correct for thermocouple measuring instruments?
a. Their calibration does
not change with time or temperature
b. Power losses are very low
c. They are incapable of
taking any overload
d. They are very useful as
transfer instruments
21. Rectifier moving coil
instrument respond to______.
a. RMS value, for
symmetrical square waveforms
b. RMS value for all
waveforms
c. Average value, for all waveforms
d. Peak value, irrespective
of the nature of the waveform
22. Which of the following
meters does not exhibit square law response?
a. Hot wire instrument
b. Electrodynamometer
c. Moving iron
d. Moving coil
23. Which one of the
following instruments is commonly used to measure the primary current of a
transformer connected to mains?
a. Moving iron meter
b. Moving coil type meter
c. Current transformer
d. Electrostatic meter
24. Decibel scale is useful
while measuring voltages covering_______.
a. Narrow voltage range
b. Narrow frequency range
c. Wide voltage ratio
d. Wide frequency ratio
25. To measure current in
the MHz range, we use an instrument of________.
a. Rectifier type
b. Electrodynamometer type
c. Thermocouple type
d. Moving iron type

0 Comments