Measurement MCQs |
1. In d.c.
potentiometer measurements, a second reading is often taken after reversing the
polarities of the d.c. supply and the unknown voltage, and the average of the
two readings is taken. This is with a view to eliminate the effect of_______.
a. Erroneous standardisation
b. Stray thermal emf’s
c. Stray magnetic fields
d. Ripples in the d.c. supply
2. In an analog data acquisition unit, what is
the correct sequence of the blocks starting from the input?
a. Signal conditioner-Recorder-Transducer
b. Signal conditioner-Transducer-Recorder
c. Transducer-Signal conditioner- Recorder
d. Transducer-Recorder-Signal conditioner
3. Which of the
following is not true regarding a flux meter?
a. The flux meter is more sensitive and accurate than the ballistic galvanometer
b. The air friction damping is negligible
c. There is no control springs
d. The industrial form of flux meter is portable
4. A distortion
analyser measures the total_____.
a. dc power
b. peak power
c. rms power
d. average power
5. A spectrum
analyser is used to display______.
a. Phase
b. Time
c. Amplitude
d. Frequency band spectrum
6. Q-factor is used
to measure_______.
a. Resistance
b. Power
c. Inductance
d. Voltage
7. Q-factor is
defined as________.
a. Reactance / Resistance
b. Resistance / Reactance
c. Resistance / Impedance
d. Impedance / Resistance
8. A frequency meter
is used to measure_______.
a. Ratio
b. Frequency
c. Time interval
d. Phase
9. Schmitt trigger
used in digital measurements time converts input to______.
a. Pulses
b. Sine wave
c. Sawtooth wave
d. Square wave
10. In an unshunted
fluxmeter, the sensitivity is dependent upon________.
a. Resistance of neither the moving coil nor the search coil
b. Resistance of both the moving coil and the search coil
c. Resistance of the search coil
d. Resistance of moving coil
11. In reed type
frequency meter, all the reeds________.
a. Have different natural frequencies, but the difference in natural frequencies of adjacent reeds is +/- 0.5 Hz
b. Have same natural frequency
c. Have different natural frequency
d. None of the above
12. In signal
generators_____.
a. Energy is converted from a simple d.c. source into a.c. energy at some specific frequency
b. Energy is generated
c. Energy is created
d. All of the above
13. Fluxmeter is a
special type of ballistic galvanometer having_______.
a. Very small electromagnetic damping and control torque
b. Very small electromagnetic damping and very high control torque
c. Very high electromagnetic damping and very small control torque
d. Very high electromagnetic damping control torque
14. Harmonic
distortion percentage is accurately measured by______.
a. VTVM
b. Harmonic distortion analyser
c. CRO
d. VOM