1. Anderson's bridge is used to measure unknown________.
a. Capacitance
b. Resistance
c. Frequency
d. Inductance
2. Hay's bridge is used to measure an inductance of
_________.
a. Low Q
b. Very high Q
c. Medium Q
d. High Q
3. To
measure precise inductance from a few μH
to several henries, which of the following bridge is used?
a.
Anderson bridge
b. Maxwell's bridge
c. Maxwell-wien bridge
d. Hay's bridge
4. Wagner's ground is used to________.
a. Measure inductance
b. Measure resistance
c. Measure capacitance
d.
Eliminate earth from the bridge network capacitance
5. Assertion (A) : The wien's bridge
may be difficult to balance unless the waveform of the applied voltage is
sinusoidal.
Reason (R) : Wien bridge is frequency
sensitive.
(a) A is true but R is false.
(b) A is false but R is false.
(c)
Both A and R are true, and R is a correct explanation of A.
(d) Both A and R are true, but R is not
a correct explanation of A.
6. Hay bridge is a modification of________.
a. Maxwell's
bridge
b. De-sauty's bridge
c. Anderson's bridge
d. None of the above
7. In wien bridge, the output frequency is determined
by_______.
a. R-L-L combination
b. R-L-C combination
c. R-C combination
d. R-L combination
8. De-sauty bridge is used for the measurement of________.
a. dissipation
factor and capacitance
b. Power factor and quality factor
c. Power factor and dissipation factor
d. Capacitance and power factor
9. The shielding of bridge elements is done to reduce the
effects of_______.
a. External magnetic field
b. Leakage current
c. Stray
capacitance
d. Distributed capacitance
10. Vibration galvanometer is tuned_______.
a. By changing the
length and tension of vibrating coil
b. By attaching weight to the vibrating coil
c. By changing its damping constant
d. All of the above
11. Wagner earth devices in AC bridge circuits are used
for_______.
a. Eliminating all
the node to earth capacitances
b. Minimizing the effect of inter-component capacitance
c. Eliminating the effect of stray capacitance
d. Shielding all the bridge elements from external
magnetic field
12. A PMMC uses
a________.
a. Moving iron type
b. Electrodynamometer
c. Moving coil
d. Taut bond
13. A moving iron movement uses______.
a. Moving coil
b. Ribbon
c. Electrodynamometer
d. Radial vane
14. Which of the following is not a desired characteristic of shunts used in PMMC instruments?
a. It should carry the current without excessive
temperature rise.
b. It should have a low thermal emf.
c. It must be
manufactured using manganin or copper
d. The resistance of the shunt should not vary with time.
15. To select the range, a multirange ammeter uses
a______.
a. Make before
break type switch
b. Simple switch
c. Single pole double throw switch
d. Double pole double throw switch